Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.877
Filtrar
1.
Zhonghua Jie He He Hu Xi Za Zhi ; 47(4): 332-338, 2024 Apr 12.
Artigo em Chinês | MEDLINE | ID: mdl-38599808

RESUMO

Objective: To assess and compare the diagnostic efficacy of next-generation ultrathin bronchoscopy (UTB) and conventional bronchoscopy (CB), both combined with radial endobronchial ultrasound (r-EBUS), in the evaluation of peripheral pulmonary lesions (PPL). Methods: A cohort of 39 patients with PPL who underwent multimodal bronchoscopy at Dushu Lake Hospital, Soochow University, from June 1, 2021 to May 31, 2023 was consecutively enrolled. A single bronchoscopist performed multimodal bronchoscopies using CB (external diameter 4.9 mm or 5.9 mm, working channel diameter 2 or 3 mm, CB group) for transbronchial biopsy under r-EBUS guidance (rEBUS-TBLB), followed by UTB (external diameter 3 mm, working channel diameter 1.7 mm, UTB group) for transbronchial biopsy under r-EBUS guidance. Pathological findings and a 6-month clinical follow-up were used as the gold standard to compare the diagnostic yield of biopsy specimens, ultrasound characteristics, and localization rates of the two bronchoscope types. The aim was to evaluate the clinical application value of UTB combined with r-EBUS. Binary variables were analysed using the McNemar test for paired data. Continuous variables or ranked data were analysed using the Wilcoxon signed-rank test for paired data. Results: The diagnostic yields for UTB and CB groups were 66.67% (26/39) and 30.77% (12/39), respectively, with the UTB group significantly surpassing the CB group (χ2=10.56, P=0.001, 1-ß=0.968). r-EBUS with CB exhibited no visible lesion in 13 cases, adjacent to the lesion in 19 cases, and within the lesion in 7 cases.Substitution of UTB resulted in r-EBUS images changing from no visible lesion to adjacent to the lesion in 7 cases, from no visible lesion to within the lesion in 3 cases, and from adjacent to the lesion to within the lesion in 12 cases. The positioning of the r-EBUS probe in relation to the lesions improved significantly with UTB usage (Z=-4.46, P<0.001). Localization rates (number of patients with "within" or "adjacent to" the image/total number of patients) for UTB and CB were 92.30% (36/39) and 66.67% (26/39), respectively (χ2=8.10, P=0.002). UTB improved r-EBUS probe localization rates. The diagnostic yields of UTB were higher than CB for solid lesions, lesions>30 mm in diameter, non-upper lobar location, benign or malignant lesions and lesions with or without a bronchus sign. Conclusion: The UTB group demonstrated a significantly higher diagnostic yield than the CB group, providing superior r-EBUS probe images, and a significant diagnostic advantage for PPL.


Assuntos
Broncoscopia , Neoplasias Pulmonares , Humanos , Broncoscopia/métodos , Neoplasias Pulmonares/patologia , Broncoscópios , Biópsia/métodos , Brônquios/patologia , Endossonografia/métodos , Estudos Retrospectivos
2.
Zhonghua Jie He He Hu Xi Za Zhi ; 47(4): 363-370, 2024 Apr 12.
Artigo em Chinês | MEDLINE | ID: mdl-38599814

RESUMO

A series of studies on the interventional diagnosis and treatment of tuberculosis(TB)were carried out by domestic and foreign researchers in 2023. The combination of minimally invasive interventional procedures with endoscopes, guidance, material acquisition techniques by multiple ways and multichannel and highly accurate laboratory testing techniques is becoming more and more widely practiced clinically, which has played an important role in the accurate diagnosis of problematic TB. Diagnostic procedures for pulmonary TB, tracheobronchial TB, mediastinal lymphatic TB and extrapulmonary TB included conventional flexible bronchoscopy and specific types of bronchoscopy(ultrathin bronchoscopy and endobronchial ultrasound), transbronchial needle aspiration biopsy, endobronchial ultrasound and virtual bronchoscopic navigation system-guided forceps biopsy, thoracoscopic cryobiopsy of pleura, percutaneous biopsy, and so on. The time to diagnosis has been significantly reduced and the diagnostic efficacy has been improved by the clinical specimen detection using either Gene Xpert MTB/RIF, Ultra, loop-mediated isothermal amplification, metagenomic next-generation sequencing, or nanopore sequencing, etc. Interventional therapy was focused on the following diseases: pulmonary TB with massive hemoptysis, tracheobronchial TB, pleural TB and TB-related fistulas. Interventional treatment of tracheobronchial TB mainly included the application of rigid bronchoscopy, bronchoscopic cold and thermal ablation treatment, endoscopic clamp, dilatations of narrow airway with balloon and stent placement, etc. The interventional treatment of pulmonary TB complicated by massive hemoptysis included endovascular embolization, coated stent placement, etc. Interventional treatment of pleural TB involved the application of thoracoscopy, endoscopic forceps, the implantation of stent and other occlusive devices and the closure of fistulas with autologous fat transplantation. In this article, we reviewed the progress of interventional diagnosis and treatment of TB by the search of published literatures from October 2022 to September 2023.


Assuntos
Fístula , Tuberculose Pleural , Tuberculose Pulmonar , Humanos , Hemoptise , Tuberculose Pulmonar/diagnóstico , Biópsia , Broncoscopia/métodos
3.
Diagn Pathol ; 19(1): 61, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38641621

RESUMO

BACKGROUND AND OBJECTIVE: EBUS-TBNA has emerged as an important minimally invasive procedure for the diagnosis and staging of lung cancer. Our objective was to evaluate the effect of different specimen preparation from aspirates on the diagnosis of lung cancer. METHODS: 181 consecutive patients with known or suspected lung cancer accompanied by hilar / mediastinal lymphadenopathy underwent EBUS-TBNA from January 2019 to December 2022. Specimens obtained by EBUS-TBNA were processed by three methods: Traditional smear cytology of aspirates (TSC), liquid-based cytology of aspirates (LBC) and histopathology of core biopsies. RESULTS: EBUS-TBNA was performed in 181 patients on 213 lymph nodes, the total positive rate of the combination of three specimen preparation methods was 80.7%. The diagnostic positive rate of histopathology was 72.3%, TSC was 68.1%, and LBC was 65.3%, no significant differences was observed (p = 0.29); however, statistically significant difference was noted between the combination of three preparation methods and any single specimen preparation methods (p = 0.002). The diagnostic sensitivity of histopathology combined with TSC and histopathology combined with LBC were 96.5 and 94.8%, the specificity was 95.0% and 97.5%, the PPV was 98.8% and 99.4%, the NPV was 86.4% and 81.2%, the diagnostic accuracy was 96.2% and 95.3%, respectively; The sensitivity and accuracy of above methods were higher than that of single specimen preparation, but lower than that of combination of three preparation methods. CONCLUSION: When EBUS-TBNA is used for the diagnosis and staging of lung cancer, histopathology combined with TSC can achieve enough diagnostic efficiency and better cost-effectiveness.


Assuntos
Neoplasias Pulmonares , Linfadenopatia , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patologia , Mediastino/diagnóstico por imagem , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Linfonodos/patologia , Linfadenopatia/patologia , Broncoscopia/métodos , Estadiamento de Neoplasias , Estudos Retrospectivos
4.
BMC Pediatr ; 24(1): 228, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561723

RESUMO

BACKGROUND: Frequent repairs of pediatric flexible bronchoscopes can lead to a huge financial burden for the hospital. This study aimed to investigate the common causes of the failures in pediatric flexible bronchoscopes and propose the measures to prevent the failures. METHODS: This was a retrospective study. We collected repair information of the pediatric flexible bronchoscopes reprocessed in the Department of Sterile Processing at a hospital between September 1, 2018 and September 1, 2022 in order to investigate the causes and possible factors associated with the failures in pediatric flexible bronchoscopes. RESULTS: The Department of Sterile Processing staff reprocessed the pediatric flexible bronchoscopes 4280 times. A total of 29 failures were identified. The failure rate was 0.678%. The average repair cost was USD7246.60. The common failures in the pediatric flexible bronchoscopes included dim video image, black dots, improper video image display or no image during angulation adjustment, and pressure marks in the insertion tube. The failure rates in flexible electronic bronchoscopes and small-diameter flexible bronchoscopes were 65.5% and 93.1%, respectively. The failure rate in the pediatric flexible bronchoscopes reprocessed by the staff members with less work experience was 75.9%. CONCLUSION: The failure rate in the pediatric flexible bronchoscopes was not high but the repair costs were extremely high. The types and size of the flexible bronchoscopes and work experience of the staff members responsible for bronchoscope reprocessing were the possible factors associated with the failure rate in the pediatric flexible bronchoscopes. It is advisable to further optimize the central workflow and management mode for reprocessing the pediatric flexible bronchoscopes, thereby extending their useful life and reducing costs.


Assuntos
Broncoscópios , Broncoscopia , Criança , Humanos , Estudos Retrospectivos , Broncoscopia/métodos , China
5.
BMC Pulm Med ; 24(1): 162, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38570737

RESUMO

BACKGROUND: Endobronchial valve (EBV) therapy, a validated method for bronchoscopic lung volume reduction (BLVR) in severe emphysema, has been explored for persistent air-leak (PAL) management. However, its effectiveness and safety in the Asian population require further real-world evaluation. In this study, we assessed the outcomes of treatment with EBV within this demographic. METHODS: We conducted a retrospective analysis of medical records from 11 Korean centers. For the emphysema cohort, inclusion criteria were patients diagnosed with emphysema who underwent bronchoscopy intended for BLVR. We assessed these patients for clinical outcomes of chronic obstructive pulmonary disease. All patients with PAL who underwent treatment with EBV were included. We identified the underlying causes of PAL and evaluated clinical outcomes after the procedure. RESULTS: The severe emphysema cohort comprised 192 patients with an average age of 70.3 years, and 95.8% of them were men. Ultimately, 137 underwent treatment with EBV. Three months after the procedure, the BLVR group demonstrated a significant improvement in forced expiratory volume in 1 s (+160 mL vs. +30 mL; P = 0.009). Radiographic evidence of lung volume reduction 6 months after BLVR was significantly associated with improved survival (adjusted hazard ratio 0.020; 95% confidence interval 0.038-0.650; P = 0.010). Although pneumothorax was more common in the BLVR group (18.9% vs. 3.8%; P = 0.018), death was higher in the no-BLVR group (38.5% vs. 54.5%, P = 0.001), whereas other adverse events were comparable between the groups. Within the subset of 18 patients with PAL, the predominant causes of air-leak included spontaneous secondary pneumothorax (44.0%), parapneumonic effusion/empyema (22.2%), and post-lung resection surgery (16.7%). Following the treatment, the majority (77.8%) successfully had their chest tubes removed. Post-procedural complications were minimal, with two incidences of hemoptysis and one of empyema, all of which were effectively managed. CONCLUSIONS: Treatment with EBV provides substantial clinical benefits in the management of emphysema and PAL in the Asian population, suggesting a favorable outcome for this therapeutic approach.


Assuntos
Enfisema , Empiema , Pneumotórax , Enfisema Pulmonar , Masculino , Humanos , Idoso , Feminino , Pneumotórax/etiologia , Pneumotórax/cirurgia , Estudos Retrospectivos , Pneumonectomia/efeitos adversos , Volume Expiratório Forçado , Broncoscopia/métodos , Empiema/etiologia , Empiema/cirurgia , Resultado do Tratamento
6.
BMC Pulm Med ; 24(1): 164, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575978

RESUMO

BACKGROUND: This study aimed to compare patient experiences during bronchoscopy procedures using either topical anesthesia (TA) or monitored anesthesia care (MA). The goal was to identify circumstances where patients could achieve similar levels of tolerance and satisfaction using only TA, especially in resource-limited settings. METHODS: This study included consecutive patients who underwent bronchoscopy with either TA or MA. Data collected included demographics, indications for bronchoscopy, procedure time, and complications during the procedure. A quality assurance survey was administered to assess patient experience and satisfaction with both procedures. A pre-specified subgroup analysis was performed based on procedure invasiveness and time. RESULTS: This study enrolled 350 (TA 251; MA 99) patients, with an average age of 65 years. Main indications for bronchoscopy included tumor diagnosis (38%), esophageal cancer staging (18%), and pulmonary infection (17%). The average duration of the procedures was 20 min, with MA being associated with a significantly longer procedure time than TA (31 min vs. 16 min; P < 0.001). The overall satisfaction rating with bronchoscopy was significantly higher in the MA group (visual analogue scale, 8.9 vs. 8.2; P = 0.001). Subgroup analyses showed that when less invasive or shorter procedures were performed, TA patients reported tolerance and satisfaction levels comparable to MA patients. CONCLUSIONS: Bronchoscopy with MA offered patients a better experience and greater satisfaction; however, in settings with limited resources, TA alone may provide similar levels of patient tolerance and satisfaction during less invasive or shorter procedures.


Assuntos
Anestesia , Pneumonia , Humanos , Idoso , Broncoscopia/métodos , Medição da Dor , Avaliação de Resultados da Assistência ao Paciente , Satisfação do Paciente
7.
Zhonghua Yi Xue Za Zhi ; 104(16): 1371-1380, 2024 Apr 23.
Artigo em Chinês | MEDLINE | ID: mdl-38644287

RESUMO

Lung cancer is the second most common malignancy with the highest mortality rate worldwide. In recent years, the rapid development of various bronchoscopic navigation techniques has provided conditions for the minimally invasive diagnosis and treatment of peripheral pulmonary nodules through the airway.Augmented reality optical lung navigation is a new technology that combined virtual bronchoscopy navigation (VBN) with augmented reality (AR) and optical navigation technology, which could assist bronchoscopist and has been widely applied in clinics. The clinical evidence certified that the navigation, has the advantages of safety and efficacy in guiding transbronchial diagnosis, localization, and treatment of pulmonary nodules. In order to standardize the clinical operation of augmented reality optical lung navigation technology and guide its application in clinical practice, Interventional Group, Society of Respiratory Diseases, Chinese Medical Association/Interventional Pulmonology Group of the Zhejiang Medical Association organized multidisciplinary experts to take the lead in formulating the Consensus of experts on transbronchial diagnosis, localization and treatment of peripheral pulmonary nodules guided by the augmented reality optical lung navigation after multiple rounds of discussion, and provided recommendation opinions and clinical guidance for the indications and contraindications, equipment and devices, perioperative treatment, operating process and complication management of peripheral pulmonary nodules applicable to augmented reality optical lung diagnosis navigation technology.


Assuntos
Realidade Aumentada , Broncoscopia , Neoplasias Pulmonares , Humanos , Broncoscopia/métodos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/cirurgia , Pulmão/cirurgia , Consenso , Nódulos Pulmonares Múltiplos/diagnóstico , Nódulos Pulmonares Múltiplos/cirurgia
8.
Sci Rep ; 14(1): 8718, 2024 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622275

RESUMO

Chronic Obstructive Pulmonary Disease (COPD) is characterized by progressive and irreversible airflow limitation, with individual body composition influencing disease severity. Severe emphysema worsens symptoms through hyperinflation, which can be relieved by bronchoscopic lung volume reduction (BLVR). To investigate how body composition, assessed through CT scans, impacts outcomes in emphysema patients undergoing BLVR. Fully automated CT-based body composition analysis (BCA) was performed in patients with end-stage emphysema receiving BLVR with valves. Post-interventional muscle and adipose tissues were quantified, body size-adjusted, and compared to baseline parameters. Between January 2015 and December 2022, 300 patients with severe emphysema underwent endobronchial valve treatment. Significant improvements were seen in outcome parameters, which were defined as changes in pulmonary function, physical performance, and quality of life (QoL) post-treatment. Muscle volume remained stable (1.632 vs. 1.635 for muscle bone adjusted ratio (BAR) at baseline and after 6 months respectively), while bone adjusted adipose tissue volumes, especially total and pericardial adipose tissue, showed significant increase (2.86 vs. 3.00 and 0.16 vs. 0.17, respectively). Moderate to strong correlations between bone adjusted muscle volume and weaker correlations between adipose tissue volumes and outcome parameters (pulmonary function, QoL and physical performance) were observed. Particularly after 6-month, bone adjusted muscle volume changes positively corresponded to improved outcomes (ΔForced expiratory volume in 1 s [FEV1], r = 0.440; ΔInspiratory vital capacity [IVC], r = 0.397; Δ6Minute walking distance [6MWD], r = 0.509 and ΔCOPD assessment test [CAT], r = -0.324; all p < 0.001). Group stratification by bone adjusted muscle volume changes revealed that groups with substantial muscle gain experienced a greater clinical benefit in pulmonary function improvements, QoL and physical performance (ΔFEV1%, 5.5 vs. 39.5; ΔIVC%, 4.3 vs. 28.4; Δ6MWDm, 14 vs. 110; ΔCATpts, -2 vs. -3.5 for groups with ΔMuscle, BAR% < -10 vs. > 10, respectively). BCA results among patients divided by the minimal clinically important difference for forced expiratory volume of the first second (FEV1) showed significant differences in bone-adjusted muscle and intramuscular adipose tissue (IMAT) volumes and their respective changes after 6 months (ΔMuscle, BAR% -5 vs. 3.4 and ΔIMAT, BAR% -0.62 vs. 0.60 for groups with ΔFEV1 ≤ 100 mL vs > 100 mL). Altered body composition, especially increased muscle volume, is associated with functional improvements in BLVR-treated patients.


Assuntos
Enfisema , Doença Pulmonar Obstrutiva Crônica , Enfisema Pulmonar , Humanos , Pneumonectomia/métodos , Qualidade de Vida , Broncoscopia/métodos , Enfisema Pulmonar/diagnóstico por imagem , Enfisema Pulmonar/cirurgia , Enfisema Pulmonar/etiologia , Enfisema/etiologia , Volume Expiratório Forçado/fisiologia , Composição Corporal , Tomografia Computadorizada por Raios X , Resultado do Tratamento
9.
BMC Pulm Med ; 24(1): 181, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627639

RESUMO

BACKGROUND: Endobronchial ultrasound-guided transbronchial cryobiopsy (EBUS-cryobiopsy) is advantageous for collecting larger specimens with minimal crushing; however, it has not been widely used for mediastinal tumors. CASE PRESENTATION: A 73-year-old woman with a history of left breast cancer underwent surgery followed by radiotherapy. Computed tomography showed a mass in the anterior mediastinum that was in extensive contact with the sternum on the ventral side and partly with the trachea on the dorsal side. Two computed tomography-guided needle biopsies (CTNBs) were performed on the mass; however, a definitive diagnosis was not made because of severe crush artifacts. Subsequently, we performed EBUS-cryobiopsy and safely obtained sufficient specimen volume with minimal crushing. The histopathological diagnosis was adenocarcinoma, with immunobiological features distinct from those of previous breast cancers. Her overall diagnosis was a rare tumor originating in the anterior mediastinum. CONCLUSIONS: EBUS-cryobiopsy can be safely performed in narrow areas surrounded by major blood vessels, and the obtained specimens may be superior to CTNBs for histopathological diagnosis.


Assuntos
Adenocarcinoma , Neoplasias Pulmonares , Humanos , Feminino , Idoso , Mediastino/patologia , Neoplasias Pulmonares/patologia , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/patologia , Endossonografia , Broncoscopia/métodos , Linfonodos/patologia
10.
Ugeskr Laeger ; 186(14)2024 Apr 01.
Artigo em Dinamarquês | MEDLINE | ID: mdl-38606703

RESUMO

Bronchoscopy has a low risk of complications when diagnosing peripheral lung lesions suspected of malignancy, however the procedures do not always determine a diagnosis. Several modalities have been invented to improve the diagnostic yield, including radial endobronchial ultrasound and electromagnetic navigation, which are currently used by several departments in Denmark. Augmented fluoroscopy, CT-guided bronchoscopy and robotic bronchoscopy are not yet available in Denmark, but may improve the diagnostic work-up, as argued in this review.


Assuntos
Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico , Broncoscopia/métodos , Fluoroscopia/métodos , Endossonografia/métodos , Pulmão/patologia
11.
BMC Cancer ; 24(1): 489, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38632507

RESUMO

BACKGROUND: Next-generation sequencing (NGS) is essential for lung cancer treatment. It is important to collect sufficient tissue specimens, but sometimes we cannot obtain large enough samples for NGS analysis. We investigated the yield of NGS analysis by frozen cytology pellets using an Oncomine Comprehensive Assay or Oncomine Precision Assay. METHODS: We retrospectively enrolled patients with lung cancer who underwent bronchoscopy at Kobe University Hospital and were enrolled in the Lung Cancer Genomic Screening Project for Individualized Medicine. We investigated the amount of extracted DNA and RNA and determined the NGS success rates. We also compared the amount of DNA and RNA by bronchoscopy methods. To create the frozen cytology pellets, we first effectively collected the cells and then quickly centrifuged and cryopreserved them. RESULTS: A total of 132 patients were enrolled in this study between May 2016 and December 2022; of them, 75 were subjected to frozen cytology pellet examinations and 57 were subjected to frozen tissue examinations. The amount of DNA and RNA obtained by frozen cytology pellets was nearly equivalent to frozen tissues. Frozen cytology pellets collected by endobronchial ultrasound-guided transbronchial needle aspiration yielded significantly more DNA than those collected by transbronchial biopsy methods. (P < 0.01) In RNA content, cytology pellets were not inferior to frozen tissue. The success rate of NGS analysis with frozen cytology pellet specimens was comparable to the success rate of NGS analysis with frozen tissue specimens. CONCLUSIONS: Our study showed that frozen cytology pellets may have equivalent diagnostic value to frozen tissue for NGS analyses. Bronchial cytology specimens are usually used only for cytology, but NGS analysis is possible if enough cells are collected to create pellet specimens. In particular, the frozen cytology pellets obtained by endobronchial ultrasound-guided transbronchial needle aspiration yielded sufficient amounts of DNA. TRIAL REGISTRATION: This was registered with the University Medical Hospital Information Network in Japan (UMINCTR registration no. UMIN000052050).


Assuntos
Neoplasias Pulmonares , Humanos , Estudos Retrospectivos , Neoplasias Pulmonares/patologia , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Broncoscopia/métodos , Sequenciamento de Nucleotídeos em Larga Escala/métodos , DNA , RNA , Linfonodos/patologia
12.
Ther Umsch ; 81(1): 21-23, 2024 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-38655830

RESUMO

INTRODUCTION: Cryobiopsies for the differentiation of interstitial pneumopathies Abstract: Definitive diagnosis of interstitial pneumopathy is often difficult. In order to establish antifibrotic therapy, it is necessary to narrow down the aetiology and, in up to 40% of cases, obtain histological confirmation. The establishment of the endoscopic method of cryobiopsy achieves a diagnostic yield of 76-80% with significantly fewer complications compared to surgical lung biopsy.


Assuntos
Doenças Pulmonares Intersticiais , Humanos , Doenças Pulmonares Intersticiais/diagnóstico , Doenças Pulmonares Intersticiais/patologia , Diagnóstico Diferencial , Biópsia , Pulmão/patologia , Criocirurgia/métodos , Broncoscopia/métodos
13.
BMC Pulm Med ; 24(1): 201, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658897

RESUMO

PURPOSE: To summarize and analyze the safety and efficacy of a Y-shape Sigma stent loaded with I125 in patients with inoperable malignant main airway obstruction. METHODS: This study was approved by the Institutional Ethics Committee, and a written informed consent was obtained from each participant. A Y-shape Sigma stent loaded with I125 was placed under vision from rigid bronchoscopy. The primary endpoint was alleviation of symptoms and improvement of Karnofsky Performance Status (KPS) score, and the secondary endpoint was complications and technical success. RESULTS: From November 2018 through June 2023, total 33 patients with malignant airway obstruction were palliatively treated by installing Y-shape Sigma stents loaded with I125. The airway lumen was immediately restored and the average airway opening significantly increased to 70 ± 9.4% after the procedure from baseline 30.2 ± 10.5% (p < 0.05). Average KPS score was improved from baseline 30.0 ± 10.0 to 70.0 ± 10.0 (p < 0.05) as well as PaO2 from baseline 50.1 ± 15.4 mmHg to 89.3 ± 8.6 mmHg (p < 0.05). The technical success rate of placing the stent in this study was 73%, and adverse events or complications including bleeding, I125 loss, and airway infection occurred during or after the procedure. CONCLUSION: Placement of Y-shape Sigma stents under vision from rigid bronchoscopy in the patients with malignant airway obstruction is feasible and it immediately alleviates dyspnea and significantly improves quality of life.


Assuntos
Obstrução das Vias Respiratórias , Broncoscopia , Radioisótopos do Iodo , Cuidados Paliativos , Stents , Humanos , Broncoscopia/métodos , Obstrução das Vias Respiratórias/terapia , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Cuidados Paliativos/métodos , Neoplasias Pulmonares/complicações , Avaliação de Estado de Karnofsky , Idoso de 80 Anos ou mais , Resultado do Tratamento , Braquiterapia/métodos , Braquiterapia/efeitos adversos , Adulto
15.
BMC Pulm Med ; 24(1): 146, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38509516

RESUMO

OBJECTIVE: Transbronchial biopsy is a safe manner with fewer complications than percutaneous transthoracic needle biopsy; however, the current diagnostic yield is still necessitating further improvement. We aimed to evaluate the diagnostic yield of using virtual bronchoscopic navigation (VBN) and cone-beam CT (CBCT) for transbronchial biopsy and to investigate the factors that affected the diagnostic sensitivity. METHODS: We retrospectively investigated 255 patients who underwent VBN-CBCT-guided transbronchial biopsy at our two centers from May 2021 to April 2022. A total of 228 patients with final diagnoses were studied. Patient characteristics including lesion size, lesion location, presence of bronchus sign, lesion type and imaging tool used were collected and analyzed. Diagnostic yield was reported overall and in groups using different imaging tools. RESULTS: The median size of lesion was 21 mm (range of 15.5-29 mm) with 46.1% less than 2 cm in diameter. Bronchus sign was present in 87.7% of the patients. The overall diagnostic yield was 82.1%, and sensitivity for malignancy was 66.3%. Patients with lesion > 2 cm or with bronchus sign were shown to have a significantly higher diagnostic yield. Four patients had bleeding and no pneumothorax occurred. CONCLUSION: Guided bronchoscopy with VBN and CBCT was an effective diagnostic method and was associated with a high diagnostic yield in a safe manner. In addition, the multivariant analysis suggested that lesion size and presence of bronchus sign could be a predictive factor for successful bronchoscopic diagnosis.


Assuntos
Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Estudos Retrospectivos , Biópsia/métodos , Tomografia Computadorizada de Feixe Cônico , Brônquios/patologia , Broncoscopia/métodos
16.
Clin Respir J ; 18(3): e13746, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38529683

RESUMO

OBJECTIVES: The aim of this study is to evaluate the diagnostic value of rapid on-site evaluation (ROSE) combined with computed tomography-guided percutaneous needle biopsy (CT-PNB) or radial endobronchial ultrasound-guided transbronchial lung biopsy (EBUS-TBLB) for pulmonary cryptococcosis (PC). METHODS: Clinical data of 33 patients diagnosed with PC at the Third Affiliated Hospital of Soochow University between February 2018 and June 2023 were retrospectively analysed. Patients were divided into the CT-PNB and EBUS-TBLB groups based on the intervention method, and the diagnostic positivity rate and incidence of complications were compared between the two groups. RESULTS: Compared with the final diagnosis, the positive diagnostic rates of ROSE, histopathology and serum CrAg of all patients were 81.8% (27/33), 72.7% (24/33) and 63.6% (21/33), respectively. The average turnaround times of the three methods were 0.1 (0.1-0.2) h, 96.0 (48.0-120.0) h and 7.8 (4.5-13.6) h, respectively (P < 0.001). The coincidence rate between histopathology and ROSE was 84.8% with a kappa value of 0.574. The positive diagnostic rate for PC was significantly higher in the CT-PNB group than in the EBUS-TBLB group (92.9% vs. 57.9%), and the difference was statistically significant (P < 0.05). Combined with the ROSE results, the positive diagnostic rate in the EBUS-TBLB group increased to 84.2% (16/19). CONCLUSION: ROSE has commendable accuracy and timeliness, and CT-PNB offers further advantages in this regard. ROSE enhances the diagnostic efficiency of EBUS-TBLB for PC and is safe and effective.


Assuntos
Criptococose , Neoplasias Pulmonares , Pneumologia , Humanos , Avaliação Rápida no Local , Estudos Retrospectivos , Broncoscopia/métodos , Biópsia Guiada por Imagem/métodos , Criptococose/diagnóstico , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patologia
17.
Medicine (Baltimore) ; 103(12): e37215, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38518001

RESUMO

BACKGROUND: To date, there is no standardized practice for the use of pharmacological sedatives during flexible bronchoscopy, particularly for elderly patients. This exploratory study aimed to assess the efficacy and safety of remimazolam at a single induced dose for deep sedation in elderly patients undergoing diagnostic flexible bronchoscopy (DFB), and compare with midazolam, a commonly used sedative. METHODS: A total of 100 elderly patients (age range 65-80 yr; American Society of Anesthesiologists Physical Status I-III) undergoing DFB were randomly allocated into 2 groups according to the sedatives used for induction: the remimazolam group and the midazolam group. Sedation induction was initiated by an intravenous bolus of remimazolam (0.135 mg/kg) or midazolam (0.045 mg/kg), respectively, both groups were combined with a high-dose of alfentanil (18 µg/kg), and supplemented with high-flow nasal cannula (HFNC) oxygen supply at a flow rate of 45 L/min. If the target depth of sedation was not achieved, propofol would be titrated as a rescue. The primary outcome was the success rate of sedation at a single induced dose to achieve target depth (Ramsay sedation score [RSS] = 4) during induction, intraoperative changes in vital signs, postoperative follow-up situation and incidence of post-bronchoscopy adverse events were evaluated as secondary outcomes. RESULTS: The success rate of sedation in the remimazolam group was significantly higher than that in the midazolam group (65.2% vs 39.6%, P = .013), while the incidence of extra sleep within 6 hours after procedure was lower in the remimazolam group as compared to the midazolam group (10.9% vs 31.3%, P = .016). No statistically significant differences were observed between the 2 groups regarding hemodynamic fluctuations, incidence of hypoxemia, and cough response during the procedure, as well as postoperative recall, willingness to undergo reexamination, and other post-bronchoscopy adverse events. CONCLUSIONS: Bolus administration of remimazolam offers advantages over midazolam for deep sedation in elderly patients undergoing DFB, in terms of a higher success rate of sedation and a lower incidence of extra sleep within 6 hours after procedure, though the safety profiles of both groups were favorable.


Assuntos
Sedação Profunda , Propofol , Humanos , Idoso , Idoso de 80 Anos ou mais , Midazolam , Broncoscopia/métodos , Benzodiazepinas , Hipnóticos e Sedativos/uso terapêutico , Método Duplo-Cego
18.
Med Eng Phys ; 125: 104116, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38508792

RESUMO

The purpose of this study was to evaluate the accuracy of a method for estimating the tip position of a fiber optic shape-sensing (FOSS) integrated instrument being inserted through a bronchoscope. A modified guidewire with a multicore optical fiber was inserted into the working channel of a custom-made catheter with three electromagnetic (EM) sensors. The displacement between the instruments was manually set, and a point-based method was applied to match the position of the EM sensors to corresponding points on the shape. The accuracy was evaluated in a realistic bronchial model. An additional EM sensor was used to sample the tip of the guidewire, and the absolute deviation between this position and the estimated tip position was calculated. For small displacements between the tip of the FOSS integrated tool and the catheter, the median deviation in estimated tip position was ≤5 mm. For larger displacements, deviations exceeding 10 mm were observed. The deviations increased when the shape sensor had sharp curvatures relative to more straight shapes. The method works well for clinically relevant displacements of a biopsy tool from the bronchoscope tip, and when the path to the lesion has limited curvatures. However, improvements must be made to our configuration before pursuing further clinical testing.


Assuntos
Broncoscopia , Fenômenos Eletromagnéticos , Broncoscopia/métodos , Imagens de Fantasmas , Cateteres
19.
Respir Investig ; 62(3): 449-454, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38522361

RESUMO

BACKGROUND: The endobronchial silicone spigot, also known as the endobronchial Watanabe spigot, is used in bronchoscopic interventions to manage prolonged pulmonary air leakage. However, the outcomes of this procedure have not been thoroughly investigated. METHODS: Using a Japanese national inpatient database from April 2014 to March 2022, we assessed the clinical characteristics and outcomes of all eligible patients who received the endobronchial spigot. We also investigated risk factors associated with treatment failure. Treatment failure was defined as in-hospital death or the need for surgery after bronchial occlusion. RESULTS: We analyzed data of 1095 patients who underwent bronchial occlusion using the endobronchial spigot. Among them, 252 patients (23.0%) died during hospitalization, and 403 patients (36.8%) experienced treatment failure. Factors associated with treatment failure included age between 85 and 94 years (odds ratio [OR] 1.83; 95% confidence intervals [CI], 1.04-3.21); male sex (OR 2.43; 95% CI, 1.44-4.11); low Barthel index score; comorbidities of interstitial pneumonia (OR 1.71; 95% CI, 1.18-2.48); antibiotics treatment (OR 1.45; 95% CI, 1.02-2.07); steroids treatment (OR 1.59; 95% CI, 1.07-2.36); and surgery prior to bronchial occlusion (OR 2.08; 95% CI, 1.29-3.35). In contrast, pleurodesis after bronchial occlusion (OR 0.49; 95% CI, 0.32-0.75), and admission to high-volume hospitals were inversely associated with treatment failure (OR 0.58; 95% CI, 0.37-0.90). CONCLUSIONS: The endobronchial Watanabe spigot could be a nonsurgical treatment option for patients with prolonged pulmonary air leaks. Our findings will help identify patients who may benefit from such bronchial interventions.


Assuntos
Obstrução das Vias Respiratórias , Pneumotórax , Humanos , Masculino , Idoso de 80 Anos ou mais , Broncoscopia/métodos , Pneumotórax/epidemiologia , Pneumotórax/etiologia , Pneumotórax/terapia , Silicones , Mortalidade Hospitalar , Resultado do Tratamento , Falha de Tratamento , Fatores de Risco
20.
Tokai J Exp Clin Med ; 49(1): 12-16, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38509007

RESUMO

A 75-year-old male visited our hospital with bilateral hilar lymph node swelling detected on chest radiography during an annual medical checkup. Chest computed tomography revealed swelling of multiple hilar mediastinal lymph nodes. Histopathological and immunohistochemical examinations of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) specimens from the hilar lymph nodes revealed amyloid deposition. Bilateral hilar and mediastinal lymphadenopathies can be the first manifestations of amyloidosis diagnosed using EBUS-TBNA.


Assuntos
Amiloidose , Neoplasias Pulmonares , Linfadenopatia , Masculino , Humanos , Idoso , Neoplasias Pulmonares/diagnóstico , Linfadenopatia/etiologia , Linfadenopatia/patologia , Mediastino/patologia , Linfonodos/patologia , Amiloidose/complicações , Amiloidose/diagnóstico , Broncoscopia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...